跟著目前(qian)我國大(da)中小型制造業企業年均激增,電(dian)網工農(nong)業持續不斷發(fa)展趨勢(shi),電(dian)焊工供給量持續不斷增強(qiang),變(bian)電(dian)氣安裝室查(cha)崗電(dian)焊工供不應求;“TYDLX-03變配電室值班電工技能培訓考核系統|供配電實訓裝置”那就是為加上變電(dian)(dian)氣安(an)裝室值勤(qin)焊(han)工(gong)(gong)考級,法(fa)(fa)律規(gui)定(ding)勞作(zuo)課和(he)(he)生活的服(fu)(fu)(fu)務(wu)(wu)保障部(bu)(bu)《變電(dian)(dian)氣安(an)裝室值勤(qin)焊(han)工(gong)(gong)崗位(wei)(wei)標準規(gui)范》,關聯性勞作(zuo)課和(he)(he)生活的服(fu)(fu)(fu)務(wu)(wu)保障部(bu)(bu)、輸配電(dian)(dian)餐飲行(xing)業崗位(wei)(wei)既(ji)能(neng)(neng)招(zhao)(zhao)(zhao)式(shi)(shi)司法(fa)(fa)評(ping)定(ding)考核評(ping)價服(fu)(fu)(fu)務(wu)(wu)服(fu)(fu)(fu)務(wu)(wu)中(zhong)心(xin)、機械裝備工(gong)(gong)農業崗位(wei)(wei)既(ji)能(neng)(neng)招(zhao)(zhao)(zhao)式(shi)(shi)司法(fa)(fa)評(ping)定(ding)考核評(ping)價服(fu)(fu)(fu)務(wu)(wu)服(fu)(fu)(fu)務(wu)(wu)中(zhong)心(xin)、綠色能(neng)(neng)源部(bu)(bu)輸配電(dian)(dian)司開發(fa)的相關內容崗位(wei)(wei)既(ji)能(neng)(neng)招(zhao)(zhao)(zhao)式(shi)(shi)司法(fa)(fa)評(ping)定(ding)考核評(ping)價書、培養教學大綱、培養輔導(dao)書、考試題庫而研制成功的。以35KV變(bian)(bian)深淺壓(ya)(ya)供(gong)電(dian)廠(chang)為一回程序模特,用位置常(chang)見、所用一回完美構件與(yu)程序模擬網管(guan)控屏(ping)相綜合的(de)組織形式,實踐教學(xue)品牌涉及到的(de)變(bian)(bian)深淺壓(ya)(ya)深淺壓(ya)(ya)供(gong)電(dian)室的(de)深淺壓(ya)(ya)電(dian)囂(xiao)與(yu)整(zheng)套設(she)配、監盤與(yu)抄表、魅力(li)繼電(dian)囂(xiao)及繼電(dian)守護、倒閘操(cao)作的(de)、常(chang)見高(gao)(gao)壓(ya)(ya)高(gao)(gao)壓(ya)(ya)電(dian)器層面等內(nei)容,會作職業技能校園、技師校園的(de)供(gong)深淺壓(ya)(ya)供(gong)電(dian)專科及相關內(nei)容專科學(xue)員實踐教學(xue)設(she)配和變(bian)(bian)深淺壓(ya)(ya)深淺壓(ya)(ya)供(gong)電(dian)室輪(lun)班水電(dian)工培訓(xun)學(xue)習年終考核技術(shu)鑒定的(de)平臺(tai)。
高、非高壓電(dian)開關與(yu)電(dian)氣成套(tao)機器的(de)(de)看法與(yu)的(de)(de)操(cao)作
1. 10kV髙壓隔離電源開關(guan)的判斷能力與(yu)運營(ying)
2. 10kV壓力進(jin)口真(zhen)空短(duan)路器(qi)的(de)判斷能力與操作流程
3. 10kV進行高壓按鈕柜的了解與進行
4. HD13型(xing)低壓低刀(dao)電開關的(de)了(le)解與(yu)操作使用(yong)
5. DW15型(xing)低電(dian)(dian)壓那么萬(wan)能的漏電(dian)(dian)斷路器的自我認同與進(jin)行(xing)
6. 血壓(ya)低壓(ya)高塑(su)殼高壓(ya)的(de)的(de)認知與操作流程
7. 0.4kV低電壓電源開關柜的自我認知與操作(zuo)流程
高、高壓(ya)低壓(ya)感(gan)應(ying)電(dian)流(liu)(liu)、電(dian)流(liu)(liu)電(dian)壓(ya)互紅外感(gan)應(ying)器的(de)的(de)認知與(yu)接電(dian)源
8. 高、低電壓直流(liu)電互傳感器的群(qun)體行為與接(jie)線柱
9. 高(gao)、血壓(ya)低壓(ya)高(gao)額定電壓(ya)互紅外感應器的自我(wo)意識(shi)與接線圖
電業繼電子元件設計看法與功能測驗
10. 電流大小繼(ji)物品的基本特性
11. 電流電壓繼家電的性(xing)能指標
12. 中間商汽車(che)繼電器開關(guan)的功能(neng)
13. 時(shi)段(duan)啟動繼電(dian)器設(she)備的性(xing)能特點
14. 閃亮(liang)繼電商的因素
15. 反期(qi)限繼電熱器的性(xing)能
供(gong)供(gong)電裝置裝置繼電保護
16. 共電新線(xian)路(lu)帶期(qi)限過電壓庇護(hu)電路(lu)板的接線(xian)頭與測試運(yun)行
17. 配電(dian)(dian)層面(mian)低壓(ya)大感應電(dian)(dian)流值初始化過感應電(dian)(dian)流保(bao)養電(dian)(dian)路系統的接(jie)法與校(xiao)準(zhun)
18. 供電(dian)(dian)設備新線(xian)路(lu)交(jiao)流電(dian)(dian)速斷維護用電(dian)(dian)線(xian)路(lu)的接電(dian)(dian)源與(yu)復位(wei)
19. 供氣路線(xian)電(dian)(dian)(dian)壓(ya)(ya)電(dian)(dian)(dian)壓(ya)(ya)反有效期(qi)過電(dian)(dian)(dian)壓(ya)(ya)電(dian)(dian)(dian)壓(ya)(ya)保養電(dian)(dian)(dian)路系統(tong)的接線(xian)柱與測(ce)試(shi)運行(xing)
20. 配(pei)電設(she)備配(pei)電變(bian)壓器過(guo)瞬時電流呵(he)護電路原理(li)的接電源與校正(zheng)
21. 配(pei)電(dian)(dian)盤干式變壓(ya)器的瞬(shun)時電(dian)(dian)流速斷守(shou)護電(dian)(dian)路(lu)系統的連接線(xian)與校(xiao)正(zheng)
22. 供配電(dian)箱式變壓器的(de)過加熱(re)器端差(cha)護理控制電(dian)路的(de)接到線與調(diao)試程(cheng)序
23. 配(pei)電變壓器的虛擬超溫庇護
供配電(dian)盤系統(tong)軟件的多次電(dian)路(lu)開關與一鍵提升(sheng)裝置(zhi)
24. 真空斷路(lu)器的掌(zhang)握和數字信號回路(lu)開關
25. 6~35KV體統的絕緣層監看部件電(dian)路板
26. 供供電設計設計一起(qi)相同閘
27. 火車線路過電流量確(que)保與自主相同閘標準化
28. 熱效率(lv)條件補充
35kV變電器站監盤與抄表
29. 單相多職(zhi)能智力儀(yi)表盤(pan)的(de)使用的(de)和(he)性能使用
30. 智力溫環境(jing)濕度調節(jie)器的用和性(xing)能設為
31. 體系運轉階段阻止(zhi)
32. 35kV雙路進線電(dian)容量(liang)監測站
33. 35kV變配電(dian)器站(zhan)主變配電(dian)器量評(ping)估(gu)
35kV變(bian)電(dian)器(qi)站倒(dao)閘操作(zuo)步(bu)驟
34. 系統運動的方法切換桌(zhuo)面倒(dao)閘運行
35. 線路圖斷電倒閘使用
36. 方式試(shi)運倒閘操作使用
37. 雙路進(jin)線電(dian)力轉二路電(dian)力倒閘操控
38. 開始進(jin)線變電(dian)轉四公(gong)里(li)變電(dian)倒閘(zha)實(shi)際操(cao)作
39. 雙母正常運(yun)作心態(tai)更換倒閘(zha)方法(fa)
40. 按(an)段(duan)單母開機運(yun)行工作狀態調(diao)節(jie)倒閘操作使用
41. 母線(xian)從正常運作感覺(jue)轉后期的維修(xiu)保養倒閘進行
42. 母線從需要(yao)維護檢修情形轉化行倒閘的操作
43. 低(di)壓變(bian)壓器從運轉情況(kuang)轉巡檢倒(dao)閘實操
44. 變電器從(cong)檢測(ce)狀運輸行倒閘進行
45. 低壓變壓器從運營(ying)工作狀態轉冷預備倒閘使用
46. 配電變壓器從運作情形轉熱備品倒閘操作的(de)
47. 配電變壓器從冷備(bei)用(yong)電源環境轉運行倒閘方法
48. 電抗(kang)器從(cong)熱自備(bei)模(mo)式轉化行倒(dao)閘操作使用
49. 出線(xian)觸點(dian)開(kai)關從運動(dong)模式轉維(wei)保(bao)倒閘工作
50. 出線從維修(xiu)動態轉冷應(ying)急倒閘使用
51. 出線(xian)從(cong)冷應(ying)急轉(zhuan)熱應(ying)急倒閘操作步驟
52. 出線從(cong)熱應急(ji)轉運行倒閘進行操作
53. 出線從(cong)檢(jian)測裝運(yun)行(xing)倒閘(zha)操(cao)作方法
54.典型案例高壓電器新線(xian)路(lu)的連(lian)接(jie)線(xian)與調校